Directional Control Valve
Series D3MW
2-55
D3MW UK.indd 27.07.22
2
Catalogue MSG11-3500/UK
Parker Hannin Corporation
Characteristics
General
Design Directional spool valve
Actuation Solenoid
Size DIN NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60
MTTF
D
value [years] 150
Weight [kg] 4.8 (1 solenoid), 6.3 (2 solenoids)
Vibration resistance [g] 10 Sinus 5...2000 Hz acc. IEC 68-2-6
30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] P, A B: 350; T: 210
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 150 (see shift limits)
Leakage at 50 bar [ml/min] Up to 20 per ow path, depending on spool
Static / Dynamic
Step response at 95 % [ms] Energized: 105
De-energized: 85
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 10000
Protection class Standard (as per EN175301-803) IP65 in acc. with EN60529
(with correctly mounted plug-in
connector)
AMP Junior Timer IP67 in acc. with EN60529
(with correctly mounted plug-in connector)
DT04-P2 “Deutsch” IP69K
(with correctly mounted plug-in connector)
Code K J
Supply voltage / ripple [V] 12 V = 24 V =
Tolerance supply voltage [%] ±10 ±10
Current consumption [A] 3 1.5
Power consumption [W] 36 36
Solenoid connection Connector as per EN 175301-803 (code W), AMP Junior Timer (code A), DT04-2P
“Deutsch” connector (code J). Solenoid ident. as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Technical data
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
AB
The D3MW is a solenoid operated directional control valve
size NG10 in 3-chamber design. It is direct operated by
wet pin solenoids.
The D3MW is designed for mobile and marine applications.
It is based on the D3W series, but oers additional corro-
sion protection of the valve body, the solenoid coil and the
anchor tube as well as the typical solenoid connections
for the mobile market such as AMP Junior Timer.
Features:
High corrosion protection (optional)
Solenoid connection:
- Standard (as per EN175301-803)
- AMP Junior Timer
- DT04-2P “Deutsch”
Robust design for rough applications
Directional Control Valve
Series D3MW
2-56
D3MW UK.indd 27.07.22
2
Catalogue MSG11-3500/UK
Parker Hannin Corporation
Ordering Code
Directional
control
valve
Wet pin
solenoid
3-chamber
valve for
mobile and
marine
applications
Spool
position
Spool
type
Size
DIN NG10
CETOP 05
NFPA D05
1)
Consider specic spool position.
2)
Please order plug separately.
3)
Only for voltage 24 V=.
D 3 WM
3 position spools
Code Spool position
C
3 positions.
Spring oset in position “0“.
Operated in position “a“ or “b“.
Standard Spool type 008, 009
E
Operated in
position “a“.
Operated in
position “b“.
2 positions.
Spring oset in position “0“.
F
Spring oset in
position “b“.
Spring oset in
position “a“.
2 positions.
Operated in position “0“.
K
Operated in
position “b“.
Operated in
position “a“.
2 positions.
Spring oset in position “0“.
M
Spring oset in
position “a“.
Spring oset in
position “b“.
2 positions.
Operated in position “0“.
2 position spools
Code Spool position
B
2 positions.
Spring oset in position “b“.
Operated in position “a“.
D
2 positions.
Operated in position “a“ or “b“.
No center or oset position.
H
2 positions.
Spring oset in position “a“.
Operated in position “b“.
3 position spools
Code Spool type
a 0 b
001
002
003
004
005
006
007
008
1)
009
1)
010
011
012
014
015
016
021
022
031
032
081
082
102
2 position spools
Code Spool type
a b
020
026
030
101
Directional Control Valve
Series D3MW
2-57
D3MW UK.indd 27.07.22
2
Catalogue MSG11-3500/UK
Parker Hannin Corporation
Ordering Code
Solenoid
options
Connection Design
series
(not required
for ordering)
Solenoid
voltage
Code Solenoid option
omit
manual override
(Standard)
T
without manual
override
Code Connection
W
2)
Connector as
per EN 175301-803
A
2) 3)
2-pin AMP
Junior Timer
J
2) 3)
Connector
DT04-P2 “Deutsch“
Code Voltage
K 12 V=
J 24 V=
Seals
Code Seals
N NBR
V FPM
Further spool types on request.
Surface
protection
Code Surface protection
omit
Standard, only for
connection “J“ and
“A“
1P
Anti corrosion
coating acc. to DIN
EN ISO 9227 NSS,
200 h for extreme
conditions.
Directional Control Valve
Series D3MW
2-58
D3MW UK.indd 27.07.22
2
Catalogue MSG11-3500/UK
Parker Hannin Corporation
Performance Curves
Flow curves
The ow curve diagram shows the ow versus pressure
drop curves for all spool types. For each spool type,
operating position and ow direction the relevant curve
number is given in the table below.
0
4
2
6
8
8
7
6
5
4
3
2
1
10
12
14
16
18
20
Pressure drop [bar]
Flow [l/min]
050 100 150
91011
All characteristic curves measured with HLP46 at 50 °C.
Position b Position a Position 0
Spool P->A B->T P->B A->T P->A P->B A->T B->T P->T A->B
001 6 5 6 6
002 3 5 3 3 1 1 4 5 1 6
003 2 2 3 1 3
004 5 4 4 4 8 8 9
005 2 2 2 2 3
006 1 2 1 3 2 2 3
007 2 1 2 2 1 2 3
010 2 2
011 2 2 2 2 11 11 11
012 1 2 2 2 10 10 10 10 11 11
014 1 2 2 2 1 2 3
015 2 1 2 2 3
016 2 2 1 2 2
020 6 6 5 7
026 5 5
030 4 5 3 5
P->B A->T P->A B->T P->A P->B A->T B->T P->T A->B
008 8 7 7 6 9
009 4 4 5 8 9
Position b Position a
P->A P->B A->B P->B A->T
021 2 4 8 3 2
P->A B->T P->A P->B A->B
022 3 2 3 2 8
Directional Control Valve
Series D3MW
2-59
D3MW UK.indd 27.07.22
2
Catalogue MSG11-3500/UK
Parker Hannin Corporation
Shift Limits
Shift limits, DC voltage
The diagrams below specify the shift limits for valves with
DC and AC solenoids. Valves with spool position “F” or
“M” can only be operated up to 70 % of the limits. The
specications apply to a viscosity of 40 mm
2
/s and bal-
anced ow conditions. The shift limits can be considerably
lower at unbalanced ow conditions. To avoid ow rates
beyond the shift limits, a plug-in orice can be inserted
in the P-port.
Measured with HLP46 at 50 °C, 90 % U
nom
and warm solenoids.
Directional Control Valve
Series D3MW
2-60
D3MW UK.indd 27.07.22
2
Catalogue MSG11-3500/UK
Parker Hannin Corporation
Dimensions
Interface EN 175301-803
B, E, F -style H, K, M -style
C, D -style
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
Dimensions with AMP Connector (only C and D -style shown)
Surface nish
BK385
4x M6x40
ISO 4762-12.9
13.2 Nm
±15 %
NBR: SK-D3W-N-30
FPM: SK-D3W-V-30
Dimensions with DT04-P2 “Deutsch“ Connector (only C and D -style shown)